ADAM-5018P
7-ch Thermocouple Input Module with Independent Input Range
High Common Mode: 2000 VDC
Fault and Overvoltage Protection: Withstands over voltage up to ±35 V
Isolation Voltage: 3,000 VDC
Filter function: Yes
Built-in TVS/ESD Protection
Input Impedance: 20 MΩ. (Build-in 120 Ω Register for Current Input)
Channels: 7 differential with Independent Input Range
CMR @ 50/60 Hz: 92 dB min
Sampling Rate: 10 samples/sec. (total)
Accuracy Bandwidth: ±0.1% or better, 13.1 Hz @ 50 Hz, 15.72 Hz @ 60 Hz